FAULT FINDING

There are a number of reasons for reduced voltage on the fence line.

TOOLS REQUIRED

The most important piece of equipment required to check for faults is the Stafix Digital Voltmeter. With the Stafix voltmeter you can pinpoint faults accurately.

Also:

FAULTS TO LOOK OUT FOR

Use the fault finding chart below to help you locate faults.

Always check the voltage at the energizer First.

To check if the energizer is faulty, disconnect both the leadout and the ground wires and test the energizer without any load. If the energizer is reading below the manufacturer's specification there could be a fault with the energizer.

If the energizer is reading normal then:

Check the Ground System before checking the fenceline.

Refer to the section on grounding in ENERGIZER INSTALLATION.

If no fault is discovered with either the energizer or the ground system, then check the fenceline.

The use of Stafix Cut Out Switches makes the job of finding faults easier as different sections of the fence can be isolated.

When the area of fence which is at fault is switched off, the voltage on the remainder of the fence will rise.

Once you have isolated the section of fence at fault, move along the fenceline and take voltage readings every 330ft.

The readings will continue to drop until you reach, or pass the fault. After the Fault, the readings should remain constant. (Remember there may be more than one fault)

INDUCTION

A phenomenon known as induction is common with electric fences. This is the transfer of electricity from an electrified wire to a non electrified wire without the wires physically touching each other. This is often mistakenly blamed on insulator leakage. This phenomenon is also more common in areas where the air is damp such as in conditions of fog.

As this phenomenon is a quirk of nature it cannot be stopped from occurring. However, to avoid receiving shocks caused by induction on non electrified fences and gates etc. you can "ground out" the offending fence by connecting a ground wire to all wires on the non electrified fence. Push the end of this wire into the ground as far as possible and this will send all the offending voltage into the ground.

Stoppng Induction

NOTE: Induction has very little effect on the voltage on the electrified fence.

RADIO INTERFERENCE

All Stafix Cyclic Wave™ energizers comply with the usual regulations, but problems can occur for various reasons, particularly in areas with poor radio reception. These are usually noticed when an audible "click" is heard on the radio and coincides with the pulsing of the energizer.

To reduce or eliminate the problem, look for faults in the following areas:

Walking the fencelines with a portable radio tuned off the station and on high volume is a quick and easy way to locate any electrical leakage.

Start

Check the voltage reading at the energizer

Is the voltage lower than normal?

Yes

Is the voltage normal?

Yes

Has the fenceline been extended or added onto?

Yes

Check that the ground voltage is not greater than 300 volts (see ENERGIZER INSTALLATION)

Yes

A larger energizer may be required but check the fenceline first

Upgrade your ground system (see ENERGIZER INSTALLATION)

Check the fenceline for possible shorting at:

Leadouts

Joints

Insulators

Vegetation growth

Accidental shorting